Difference between revisions of "System attributes"
| (One intermediate revision by one other user not shown) | |||
| Line 11: | Line 11: | ||
(" GATE_TYPE", "gated_clock") | (" GATE_TYPE", "gated_clock") | ||
(" creating_port_refs", "1") | (" creating_port_refs", "1") | ||
| − | (" enum_encoding", user_encoding) // DFF | + | (" enum_encoding", user_encoding) // DFF |
| − | (" PROCESS_ID", buffer) // ReadPort/WritePort only | + | (" PROCESS_ID", buffer) // ReadPort/WritePort only |
| − | (" is_concurrent", "1") // ReadPort/WritePort only | + | (" is_concurrent", "1") // ReadPort/WritePort only |
| − | (" BLOCKING", "1") // ReadPort/WritePort only | + | (" BLOCKING", "1") // ReadPort/WritePort only |
| + | (" instantiated_primitive", "1") // for directly-instantiated Verilog primitives | ||
| + | (" instantiated_vfc_primitive", "1") // for directly-instantiated Verific primitives | ||
(" from_array_inst", (full_name)?full_name:inst_name) | (" from_array_inst", (full_name)?full_name:inst_name) | ||
| − | |||
Net | Net | ||
| − | |||
(" wired", "1") | (" wired", "1") | ||
(" is_up_dir", "1") | (" is_up_dir", "1") | ||
| − | (" | + | (" basic_constant", const_val) // is driven by a constant and also connected to a blackbox |
| − | (" original_name", name) // original name | + | (" init_val", value) // initial value if compile flag DB_PRESERVE_INITIAL_VALUE enabled |
| − | (" supply0", "1") // from Verilog "supply0" construct | + | (" original_name", name) // original name per input file for renamed nets to avoid to name conflict |
| − | (" supply1", "1") // from Verilog "supply1" construct | + | (" supply0", "1") // from Verilog "supply0" construct |
| − | (" specify_cond", cond_pp) // SDF only | + | (" supply1", "1") // from Verilog "supply1" construct |
| − | + | (" specify_cond", cond_pp) // SDF only | |
| − | (" global_clocking_ref", "1") // SVA | + | (" global_clocking_ref", "1") // SVA |
| − | (" sva_clock_ref", "1") // SVA | + | (" sva_clock_ref", "1") // SVA |
(" enum_encoding", user_encoding) | (" enum_encoding", user_encoding) | ||
| + | (" package_net", "1") | ||
NetBus | NetBus | ||
(" original_name", name) | (" original_name", name) | ||
Port | Port | ||
(" orig_port_name", name) | (" orig_port_name", name) | ||
| − | (" | + | (" init_val", value) // initial value, if compile flag DB_PRESERVE_INITIAL_VALUE is enabled |
| − | (" created_from_test_cell", "1") // created from test cell in SynLib | + | (" created_from_test_cell", "1") // created from test cell in SynLib |
(" open_port", "1") | (" open_port", "1") | ||
PortBus | PortBus | ||
(" orig_port_name", name) | (" orig_port_name", name) | ||
Netlist | Netlist | ||
| − | (" language", language_name) // the language | + | (" language", language_name) // the language of origin: "edif", "verilog", "vhdl", "upf", "synlib", "upf" |
| − | (" cell_name", module_name) // original module/unit name in input file | + | (" cell_name", module_name) // original module/unit name in input file |
| − | (" from_netlist_reader", "1") // from structural netlist reader (not synthesized from RTL) | + | (" from_netlist_reader", "1") // from structural netlist reader (not synthesized from RTL) |
| − | (" primitive", "1") // netlist is a | + | (" primitive", "1") // netlist is a UDP primitive |
| − | (" unknown_design", "2")) // "1" for Verilog instance, "2" for VHDL instance | + | (" unknown_design", "2")) // "1" for Verilog instance, "2" for VHDL instance |
| + | (" celldefine","1") // netlist has "`celldefine" directive | ||
| + | (" package", "1") // netlist comes from a VHDL package | ||
| + | (" upf_uniquified", "1")) // from ups reader | ||
| + | (" is_sequential", 0) // from synlib reader | ||
| + | (" is_latch", 0) // from synlib reader | ||
(" changed_by_interface_overwrite", "1") | (" changed_by_interface_overwrite", "1") | ||
(" changed_by_hier_ref", "1") | (" changed_by_hier_ref", "1") | ||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
</nowiki> | </nowiki> | ||
Latest revision as of 09:54, 29 June 2026
Verific system attributes are attributes added and attached to DesignObjs (Design Objects) during the process of building the Netlist Database.
To distinguish with user-declared attributes, the key (name) of a system attribute has a space as the first character.
System attributes are not written out in the Verilog netlist output, unless when the runtime flag "db_verilog_writer_write_internal_data" is enabled.
Below is the list of system attributes in the Netlist database. Note that depending on the flow, a DesignObj may or may not have a particular attribute. Some attributes depend on runtime flag settings.
Instance
(" named_group", named_group)
(" GATE_TYPE", "gated_clock")
(" creating_port_refs", "1")
(" enum_encoding", user_encoding) // DFF
(" PROCESS_ID", buffer) // ReadPort/WritePort only
(" is_concurrent", "1") // ReadPort/WritePort only
(" BLOCKING", "1") // ReadPort/WritePort only
(" instantiated_primitive", "1") // for directly-instantiated Verilog primitives
(" instantiated_vfc_primitive", "1") // for directly-instantiated Verific primitives
(" from_array_inst", (full_name)?full_name:inst_name)
Net
(" wired", "1")
(" is_up_dir", "1")
(" basic_constant", const_val) // is driven by a constant and also connected to a blackbox
(" init_val", value) // initial value if compile flag DB_PRESERVE_INITIAL_VALUE enabled
(" original_name", name) // original name per input file for renamed nets to avoid to name conflict
(" supply0", "1") // from Verilog "supply0" construct
(" supply1", "1") // from Verilog "supply1" construct
(" specify_cond", cond_pp) // SDF only
(" global_clocking_ref", "1") // SVA
(" sva_clock_ref", "1") // SVA
(" enum_encoding", user_encoding)
(" package_net", "1")
NetBus
(" original_name", name)
Port
(" orig_port_name", name)
(" init_val", value) // initial value, if compile flag DB_PRESERVE_INITIAL_VALUE is enabled
(" created_from_test_cell", "1") // created from test cell in SynLib
(" open_port", "1")
PortBus
(" orig_port_name", name)
Netlist
(" language", language_name) // the language of origin: "edif", "verilog", "vhdl", "upf", "synlib", "upf"
(" cell_name", module_name) // original module/unit name in input file
(" from_netlist_reader", "1") // from structural netlist reader (not synthesized from RTL)
(" primitive", "1") // netlist is a UDP primitive
(" unknown_design", "2")) // "1" for Verilog instance, "2" for VHDL instance
(" celldefine","1") // netlist has "`celldefine" directive
(" package", "1") // netlist comes from a VHDL package
(" upf_uniquified", "1")) // from ups reader
(" is_sequential", 0) // from synlib reader
(" is_latch", 0) // from synlib reader
(" changed_by_interface_overwrite", "1")
(" changed_by_hier_ref", "1")
To access the attributes of a DesignObj, use macro FOREACH_ATTRIBUTE. For example:
C++:
Netlist *netlist = ....; // or any other derived class from DesignObj
Att *attr;
MapIter mi;
FOREACH_ATTRIBUTE(netlist, mi, attr) {
const char *key = (attr) ? attr->Key() : 0 ;
if (!key) continue ;
if (key[0] == ' ') continue ; // if you want to skip system attributes
// Do whatever you want here, e.g.
Message::Msg(VERIFIC_INFO, 0, 0, " -- attribute name: %s, value: %s", attr->Key(), attr->Value());
}
You can get a particular attribute. For example:
if (netlist->GetAttValue(" language")) {
Message::Msg(VERIFIC_INFO, 0, 0, " from %s", netlist->GetAttValue(" language"));
} else {
Message::Msg(VERIFIC_INFO, 0, 0, " no language");
}